Post on 03-Jun-2018
transcript
8/12/2019 Localizacin y Solucin de Problemas 789c
1/28
Localizacin y Solucin de Problemas784C, 785B, 785C, 785D, 789B, 789C, 793B, 793C, 793D, 797 and 797B Off-Highway Truck/Tractors Vital Information Management System (VIMSTM)
Nmero de medio -RENR2631-07 Fecha de publicacin -01/07/2009 Fecha de actualizacin -06/07/2009
i02415716
Diagnostic Capabilities
SMCS -1400
/sisw eb/sisw eb/ /sisw eb/product
The Caterpillar Electronic Technician (ET)
Ver imagen
Illustration 1g00777826
The Caterpillar Electronic Technician (ET) is a software program that is used to access
data. The service technician can use the ET in order to perform maintenance on the
machine. Some of the options that are available with the Caterpillar Electronic Technicianare listed below:
View diagnostic codes. See Troubleshooting, "Using the Caterpillar ElectronicTechnician to Determine Diagnostic Codes".
Viewing active event codes and logged event codes View the status of parameters. Clear active diagnostic codes and clear logged diagnostic codes Perform calibration of machine systems. Program the ECM (Flash). This is done with the "WINflash" program. See Testing
and Adjusting, "Electronic Control Module (ECM) - Flash Program".
Print reports.
The following list contains some of the diagnostic functions and programming functions
that are performed by the service tools.
The failures of the ECM system are displayed. The status of most of the inputs and the outputs are displayed. The settings for the ECM are displayed.
http://viewimage%28%27g00777826%27%2C%27d%27%29/http://viewimage%28%27g00777826%27%2C%27d%27%29/http://viewimage%28%27g00777826%27%2C%27d%27%29/8/12/2019 Localizacin y Solucin de Problemas 789c
2/28
Display the status of the input and output parameters in real time. Display the clock hour of the internal diagnostic clock. The number of occurrences and the clock hour of the first occurrence and the last
occurrence is displayed for each logged diagnostic code.
The definition for each logged diagnostic code and each event is displayed.
Load new FLASH software.
See Troubleshooting, "Diagnostic Code List" for the list of diagnostic codes for the ECM.
Active diagnostic codes Logged diagnostic codes
Event Codes
Logged Event Codes
Ver imagen
Illustration 2g00803746
Typical ET screen for logged events
An indicator for logged events is provided. The indicator allows the service technician tokeep track of event codes that are intermittent. The data for the logged event will include
the following information:
An event identifier (EID) A text description of the problem The number of occurrences of the problem A time stamp will display the first occurrence of the problem. A time stamp will display the last occurrence of the problem.
Status Groups For The Electronic Technician
The Status groups are lists of machine parameters. The status of the parameters are shown
in real time.
Ver imagen
http://viewimage%28%27g00803746%27%2C%27d%27%29/http://viewimage%28%27g00803746%27%2C%27d%27%29/http://viewimage%28%27g00496395%27%2C%27d%27%29/http://viewimage%28%27g00496395%27%2C%27d%27%29/http://viewimage%28%27g00496395%27%2C%27d%27%29/http://viewimage%28%27g00803746%27%2C%27d%27%29/8/12/2019 Localizacin y Solucin de Problemas 789c
3/28
Illustration 3g00496395
Typical Cat ET Status Screen
Configuring Diagnostics
The VIMS 10.3 and later software allow the user to configure the diagnostic operations ofthe VIMS ECM for the options that are listed below via the Caterpillar Electronic
Technician (ET):
Output drivers of the VIMS ECM for lamps, Light emitting diodes and solenoids. The preheating of the lamps by the VIMS ECM
Procedure
1. Connect a laptop computer with the Caterpillar Electronic Technician (ET) to theservice connector of the machine via the communication adapter.
2. Turn the disconnect key and the key start switch to the ON position.3. Start the Caterpillar Electronic Technician (ET) and establish communication with
the machine.
Ver imagen
Illustration 4g00895412
Ver imagen
Illustration 5g00895419
4. Select the "Configuration" option of the "Service" menu or press the "F5" key. Thiswill display the "Configuration" screen. Refer to Illustration 6.
Ver imagen
http://viewimage%28%27g00895412%27%2C%27d%27%29/http://viewimage%28%27g00895412%27%2C%27d%27%29/http://viewimage%28%27g00895419%27%2C%27d%27%29/http://viewimage%28%27g00895419%27%2C%27d%27%29/http://viewimage%28%27g01207504%27%2C%27d%27%29/http://viewimage%28%27g01207504%27%2C%27d%27%29/http://viewimage%28%27g01207504%27%2C%27d%27%29/http://viewimage%28%27g00895419%27%2C%27d%27%29/http://viewimage%28%27g00895412%27%2C%27d%27%29/8/12/2019 Localizacin y Solucin de Problemas 789c
4/28
Illustration 6g01207504
5. Select the parameter. You may configure the output diagnostics for the parametersthat are listed in Table 1.
Table 1
Output Parameters of the VIMS
Description Values
"Payload Coeff"
"785 (6549)" (1)
"789 (5928)" (1)
"793 (3209)" (1)
"797 (13385)" (1)
"Empty Machine Wt" "xxx.xxx" (2)
"Tkph R Axle Empty Weight" "xxx.x"
"Tkph F Axle Empty Weight" "xxx.x"
"Tkph Speed Limit" "xx.x"
"Tkph Time Base" "x"
"Tkph F Tire Activation" "xxxx"
"Tkph F Tire Deactivation" "xxxx"
"Tkph R Tire Activation" "xxxx"
"Tkph R Tire Deactivation" "xxxx"
"Warning Lamp Configuration"
"Incandescent lamp" (3)
"LED" (4)
"External Service Lamp"
"Incandescent lamp" (3)
"LED" (4)
"Green TPMS Lamp Installation Configuration" "Installed" (3)
8/12/2019 Localizacin y Solucin de Problemas 789c
5/28
"Incandescent lamp" (3)
"LED" (4)
"Red TPMS Lamp Installation Configuration"
"Installed" (3)
"Incandescent lamp" (3)
"LED" (4)
"Hydraulic Control Valve Warm Up Solenoid #1
Installation Status"
"Installed" (3)
"Not Installed" (4)
"Hydraulic Control Valve Warm Up Solenoid #2
Installation Status"
"Installed" (3)
"Not Installed" (4)
) The values for each model are the standard value. Do not adjust unless authorized.( 2 ) These values are configurabel only if TKPH is activated through the attachment code.
) This is the default setting.The diagnostics are enabled.( 4 ) Diagnostics are disabled.
6. Click on the "Change" button that is located on the "Configuration" screen. Thiswill display a dialog box.
Ver imagen
Illustration 7g00897656
7. Click on the down arrow on the right hand side of the dialog box. This will displaythe settings that are available for the parameter.
8. Highlight the new value and click on the "OK" button. This will cause the Cat ET todisplay the following message:
Ver imagen
Illustration 8g00827549
http://viewimage%28%27g00897656%27%2C%27d%27%29/http://viewimage%28%27g00897656%27%2C%27d%27%29/http://viewimage%28%27g00827549%27%2C%27d%27%29/http://viewimage%28%27g00827549%27%2C%27d%27%29/http://viewimage%28%27g00827549%27%2C%27d%27%29/http://viewimage%28%27g00897656%27%2C%27d%27%29/8/12/2019 Localizacin y Solucin de Problemas 789c
6/28
9. Click on the "Yes" button in order to change the parameter setting. Click on the"No" button in order to cancel the change of the parameter setting.
Vital Information Management System (VIMS)
Ver imagen
Illustration 9g00503941
Gauge Cluster Module
(1) Gauge warning area
(2) Pictograph symbol
Ver imagen
Illustration 10g00503942
Speedometer and Tachometer Module
(3) Tachometer
(4) Pictograph symbol
(5) Ground speed readout
(6) Actual gear readout
Ver imagen
Illustration 11g00503965
Message Center Module
(7) Alert indicator
(8) Data logging indicator
http://viewimage%28%27g00503941%27%2C%27d%27%29/http://viewimage%28%27g00503941%27%2C%27d%27%29/http://viewimage%28%27g00503942%27%2C%27d%27%29/http://viewimage%28%27g00503942%27%2C%27d%27%29/http://viewimage%28%27g00503965%27%2C%27d%27%29/http://viewimage%28%27g00503965%27%2C%27d%27%29/http://viewimage%28%27g00503965%27%2C%27d%27%29/http://viewimage%28%27g00503942%27%2C%27d%27%29/http://viewimage%28%27g00503941%27%2C%27d%27%29/8/12/2019 Localizacin y Solucin de Problemas 789c
7/28
(9) Message area
(10) Universal gauge
(11) Gauge warning area
This section contains a brief overview of the VIMS. This section contains the information
that is needed to complete the following tasks.
Get the diagnostic codes. Run the service procedures. Clear the diagnostic codes.
Note: For a full description of the VIMS, see Service Manual, RENR2630, "Vital
Information Management System".
The VIMS display components show the following information to the operator and/or theservice person.
The VIMS is operating properly. The key start switch is turned to the ON position.Some of the VIMS outputs operate briefly. The VIMS performs a self test of the
system.
The VIMS displays a value for the system condition. The VIMS continuouslymonitors all machine systems.
An abnormal condition of a machine system (data event) exists. The VIMScontinuously monitors the machine systems. When an abnormal condition exists,
the alert indicator (7) FLASHES. Also, the message area (9) shows the systemparameter that has an abnormal condition. Universal gauge (10) also shows the
approximate value of the abnormal parameter. The event is stored in the mainmodule memory. As the severity of the problem increases the action lampFLASHES and the action alarm SOUNDS. See Service Manual, RENR2630, "Vital
Information Management System".
The VIMS continuously checks for electrical problems in the VIMS. The VIMSmonitors the other electronic control module systems on the machine. The VIMS
continuously checks for failures, when a failure already exists. A detected
maintenance event is shown on the message area. A detected maintenance event is
stored in the memory of the main module. See "Service Operations".
The VIMS enters normal mode when the VIMS is powered up. Initiate a service operation
with the keypad in order to exit the normal mode. See "Service Operations".
Service Operations
The operator and/or the service person can initiate numerous VIMS service operations. Aservice program code (SPC) is assigned to each service operations. Use the keypad to enter
8/12/2019 Localizacin y Solucin de Problemas 789c
8/28
the service program code into the VIMS. The service program code initiates the
corresponding server operation. Some of the service operations are listed in this table.
Table 2
VIMS Service Operations
Service OperationsService Program Code
Service Program
CodeNumber
Attachment Code - Configure "ATTACH" 288224
Data Logger - Reset "DLRES" 35737
Data Logger - Start/Stop "DLOG" 3564
Display Backlighting - Set "BLT" 258
Display Contrast - Set "CON" 266
Display Language - Set "LA" 52
Display Units - Set "UN" 86
Event - Configure "ESET" (1) 3738
Event Acknowledged - Show "EACK" 3225
Event Lists - Show "ELIST" 35478
Event Statistics - Show "ESTAT" 37828
Lubrication Interval - Set "LUBSET" 582738
Lubrication Manual - Start "LUBMAN" 582626
Machine Status - Show "MSTAT" 67828
Odometer - Set "ODO" 636
Payload - Calibrate "PAYCAL" (1) 729225
Payload - Configure "PAYCONF" (1) 7292663
Resettable Totals - Reset "RESET" 73738
Resettable Totals - Show "TOT" 868
Road Analysis Control Sensitivity -
Set"RAC" (1) 722
8/12/2019 Localizacin y Solucin de Problemas 789c
9/28
Service Lamp - Reset "SVCLIT" 782548
Service Lamp - Set (1) "SVCSET" 782738
Snapshot Trigger - Configure "ERSET" (1) 37738
System Self Test "TEST" 8378
VIMS Snapshot - Start "EREC" 3732
) This command can only be performed when the VIMS is connected to the machine.
"OK" Key- This key is used to complete entries on the keypad. This key is also used to
acknowledge events. Acknowledging an event will remove the event from the display
temporarily. Severe events cannot be acknowledged.
"Gauge Key"- The VIMS displays the checked parameters when the key is pressed.
Depressing the arrow keys will scroll through the parameters. First enter the parameternumber. Then, press the "F1" Key. The "F1" key provides additional information about theevent that is being displayed. The "MID-CID-FMI" is displayed for the maintenance
events. The current parameter value is displayed for data events.
Each service program code is a unique number of one to ten digits. The service program
codes have a equivalent letter that describes the service operation. The letter equivalentallows an easier way to remember the service program code for the operation. The English
letter equivalent for each service program code is shown in the parentheses. Different on
board languages have no effect on the codes.
After entering the service program code on the keypad, the service code must becompleted by pressing the "OK" key within five seconds after entering the last SPC
character.
Note: For a full description of the VIMS, see Service Manual, RENR2630, "Vital
Information Management System".1 1 1
g00503941 /sisw eb/sisw eb/ i01731237
/sisw eb/sisw eb/ /sisw eb/sisw eb/ /sisw eb/product
null g00503941 %2Fsisw eb%2F Pantalla+anterior Y null
null %2Fsisw eb%2F
8/12/2019 Localizacin y Solucin de Problemas 789c
10/28
Copyright 1993 - 2009 Caterpillar Inc.Todos los derechos reservados.Red privada para licenciados del SIS.
Sun Nov 22 14:37:26 EST 2009
Localizacin y Solucin de Problemas784C, 785B, 785C, 785D, 789B, 789C, 793B, 793C, 793D, 797 and 797B Off-
Highway Truck/Tractors Vital Information Management System (VIMSTM
)
Nmero de medio -RENR2631-07 Fecha de publicacin -01/07/2009 Fecha de actualizacin -06/07/2009
i02415767
Diagnostic Code List
SMCS -7569
/sisw eb/sisw eb/ /sisw eb/product
Use the Vital Information Management System (VIMS) or the Caterpillar Electronic
Technician (ET) in order to determine the diagnostic codes for the VIMS electronic controlmodule (ECM). After determining the diagnostic codes, refer to the corresponding test
procedure for more information. Perform the procedure that corresponds to the Component
Identifier (CID) and the Failure Mode Identifier (FMI) of the diagnostic code. The
following table is a list of possible diagnostic codes for the VIMS ECM.
Table 1
Diagnostic Codes For the VIMS ECM
Module Identifier (MID 049) (1)
Perform the procedure that corresponds to the CID and the FMI of the diagnostic
code during troubleshooting.
CID / FMI Description
CID 0041 Sensor Power Supply (+8 Volt)
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
CID 0075 Steering Oil Temperature Sensor
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
http://opencopyrightwindow%28%29/http://opencopyrightwindow%28%29/http://opencopyrightwindow%28%29/http://opencopyrightwindow%28%29/http://opencopyrightwindow%28%29/http://opencopyrightwindow%28%29/8/12/2019 Localizacin y Solucin de Problemas 789c
11/28
CID 0096 Fuel Level Sensor
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
CID 0171 Ambient Air Temperature Sensor
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
CID 0248 Cat Data Link
FMI 09 Abnormal Update.
CID 0267 Remote Shutdown Input
FMI 01 Data Below Normal.
CID 0271 Action Alarm
FMI 03 Voltage above normal or shorted high.
FMI 05 Current below normal or open circuit.
FMI 06 Current above normal or grounded circuit.
CID 0279 Front Aftercooler Coolant Temperature Sensor
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
CID 0296 Transmission Electronic Control Module
FMI 02 Data Erratic or intermittent or incorrect.
FMI 09 Abnormal update.
FMI 12 Bad Device or Component.
CID 0324 Lamp (Action)
FMI 03 Voltage above normal or shorted high.
8/12/2019 Localizacin y Solucin de Problemas 789c
12/28
FMI 05 Current below normal or open circuit.
FMI 06 Current above normal or grounded circuit.
CID 0379 Auto Lube Pressure Sensor
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
CID 0431 Steering Oil Level Sensor
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
CID 0533 Auto Retarder Electronic Control Module
FMI 02 Data Erratic or intermittent or incorrect.
FMI 09 Abnormal update.
FMI 12 Bad Device or Component.
CID 0590 Engine Electronic Control Module
FMI 02 Data Erratic or intermittent or incorrect.
FMI 09 Abnormal update.
FMI 12 Bad Device or Component.
CID 0654 Trailer Right Brake Oil Temperature Sensor
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
CID 0655 Trailer Left Brake Oil Temperature Sensor
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
8/12/2019 Localizacin y Solucin de Problemas 789c
13/28
CID 0656 Trailer Brake Cooler Inlet Temperature Sensor
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
CID 0657 Trailer Brake Cooler Outlet Temperature Sensor
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
CID 0658 Trailer Right Strut Pressure Sensor
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
CID 0659 Trailer Left Strut Pressure Sensor
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
CID 0703 Trailer Door Position Sensor
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
CID 0809 Speedometer/Tachometer Module (No. 1)
FMI 02 Data Erratic or intermittent or incorrect.
FMI 12 Bad Device or Component.
CID 0810 Speedometer/Tachometer Module (No. 2)
FMI 02 Data Erratic or intermittent or incorrect.
FMI 12 Bad Device or Component.
8/12/2019 Localizacin y Solucin de Problemas 789c
14/28
CID 0811 Gauge Cluster (No. 1)
FMI 02 Data Erratic or intermittent or incorrect.
FMI 12 Bad Device or Component.
CID 0812 Gauge Cluster (No. 2)
FMI 02 Data Erratic or intermittent or incorrect.
FMI 12 Bad Device or Component.
CID 0813 Gauge Cluster (No. 3)
FMI 02 Data Erratic or intermittent or incorrect.
FMI 12 Bad Device or Component.
CID 0814 Gauge Cluster (No. 4)
FMI 02 Data Erratic or intermittent or incorrect.
FMI 12 Bad Device or Component.
CID 0815 Message Center (No. 1)
FMI 02 Data Erratic or intermittent or incorrect.
FMI 12 Bad Device or Component.
CID 0816 Message Center (No. 2)
FMI 02 Data Erratic or intermittent or incorrect.
FMI 12 Bad Device or Component.
CID 0817 ECM Backup Battery
FMI 02 Data Erratic or intermittent or incorrect.
FMI 12 Bad Device or Component.
CID 0819 Display Data Link
FMI 02 Data Erratic or intermittent or incorrect.
FMI 03 Voltage above normal or shorted high.
FMI 06 Current above normal or grounded circuit.
FMI 12 Bad Device or Component.
8/12/2019 Localizacin y Solucin de Problemas 789c
15/28
CID 0820 Keypad Data Link
FMI 02 Data Erratic or intermittent or incorrect.
FMI 03 Voltage above normal or shorted high.
FMI 06 Current above normal or grounded circuit.
FMI 12 Bad Device or Component.
CID 0821 Display Power Supply (12 Volts)
FMI 03 Voltage above normal or shorted high.
FMI 06 Current above normal or grounded circuit.
CID 0823 Lamp (Service Indicator)
FMI 03 Voltage above normal or shorted high.
FMI 05 Current below normal or open circuit.
FMI 06 Current above normal or grounded circuit.
CID 0824 Lamp (Truck Payload) (Green)
FMI 03 Voltage above normal or shorted high.
FMI 05 Current below normal or open circuit.
FMI 06 Current above normal or grounded circuit.
CID 0825 Lamp (Truck Payload) (Red)
FMI 03 Voltage above normal or shorted high.
FMI 05 Current below normal or open circuit.
FMI 06 Current above normal or grounded circuit.
CID 0833 Rear Brake Oil Temperature Sensor
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
CID 0838 Left Front Suspension Cylinder Pressure Sensor
FMI 03 Voltage above normal or shorted high.
8/12/2019 Localizacin y Solucin de Problemas 789c
16/28
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
CID 0839 Right Front Suspension Cylinder Pressure Sensor
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
CID 0840 Left Rear Suspension Cylinder Pressure Sensor
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
CID 0841 Right Rear Suspension Cylinder Pressure Sensor
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
CID 0852 Right Front Brake Oil Temperature Sensor
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
CID 0853 Left Front Brake Oil Temperature Sensor
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
CID 0854 Right Rear Brake Oil Temperature Sensor
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
8/12/2019 Localizacin y Solucin de Problemas 789c
17/28
CID 0855 Left Rear Brake Oil Temperature Sensor
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
FMI 08 Abnormal Frequency, Pulse Width or Period.
CID 0890 Telemetry Data Link
FMI 09 Abnormal update.
CID 1421 Rear Engine Electronic Control Module
FMI 02 Data Erratic or intermittent or incorrect.
FMI 09 Abnormal update.
FMI 12 Bad Device or Component.
CID 1422 Front Engine Electronic Control Module
FMI 02 Data Erratic or intermittent or incorrect.
FMI 09 Abnormal update.
FMI 12 Bad Device or Component.
( 1 ) For the VIMS ECM, the MID is 049. This table pertains only to faults with a MID of 049.
Note: Table 1 refers to the diagnostic codes for the VIMS ECM only. The diagnostic codes
for the VIMS ECM are shown on the display area of the Vital Information ManagementSystem (VIMS). The module identifier (MID) tells the service person the ECM that is
sending the diagnostic code. The MID for the VIMS ECM is 049. The information in table
1 only refers to diagnostic codes with a MID of 049. The MID of other electronic controlmodules or components on a particular machine are listed on the electrical system
schematic. Troubleshooting information for the diagnostic codes with a MID that is not 049
can be found in the service manual for that system.
ReferenceFor more information on the Vital Information Management System (VIMS),
refer to the Service Manual module Troubleshooting, "Using Vital InformationManagement System to Determine Diagnostic Codes".
Module Identifier (MID)
Diagnostics from other electronic control modules are shown on the monitoring system.
Other electronic control modules transfer this diagnostic information on the Cat Data Link
to the monitoring system.
8/12/2019 Localizacin y Solucin de Problemas 789c
18/28
The module identifier (MID) identifies the electronic control module that detected the fault.
Each electronic control module on the machine has a unique MID. Use the following chart
in order to match the MID for each diagnostic code to a specific electronic control module.
The chart for the Module Identifier (MID) is located on the Electrical System Schematic foryour machine. See the chart if the MID is not shown on the display of your machine. After
the operator determines the electronic control module that has detected the failure, see theservice manual module for that particular ECM for more troubleshooting information. Theservice manual for each ECM is part of the machine's Service Manual.
If the MID is for the VIMS ECM, use this service manual module. The MID for the VIMSECM is 049. If the MID is different use the appropriate module.
Table 2
Description of the Module Identifier
MID Description
027 Transmission Control (EPTC II only)
033 Front Engine Control
034 Rear Engine Control
036 Engine ECM
049 Vital Information Management System (VIMS)
081 Transmission Electronic Control
082 Implement Control
083 Automatic Retarder Control
087 Chassis Control Module
116 Brake Control
173 Unknown Fault of MID
Failure Mode IdentifierThe codes for the Failure Mode Identifier are defined by the SAE standards. The followinglist contains a CAT version of definitions. The diagram that follows will help you
understand the use of FMI with sensors.
8/12/2019 Localizacin y Solucin de Problemas 789c
19/28
Ver imagen
Illustration 1g00493694
Table 3
Failure Mode Identifier and Message Center Displays
FMI "Failure Description"
00 "Data valid but above normal operating range"
01 "Data valid but below normal operating range"
02 "Data erratic, intermittent or incorrect"
03 "Voltage above normal or shorted high"
04 "Voltage below normal or shorted low"
05 "Current below normal or open circuit"
06 "Current above normal or grounded circuit"
07 "Mechanical system not responding properly"
08 A"bnormal frequency, pulse, or period"
09 "Abnormal update"
10 "Abnormal rate of change"
http://viewimage%28%27g00493694%27%2C%27d%27%29/http://viewimage%28%27g00493694%27%2C%27d%27%29/http://viewimage%28%27g00493694%27%2C%27d%27%29/8/12/2019 Localizacin y Solucin de Problemas 789c
20/28
11 "Failure mode not identifiable"
12 "Bad device or component"
13 "Out of calibration"
14 N/A
15 N/A
16 "Parameter not available"
17 "Module not responding"
18 "Sensor supply fault"
19 "Condition not met"
20 N/A
Detailed FMI Explanation
FMI 00 "Data Valid But Above Normal Operating Range"- Every electronic control
system sets a high limit for the expected operating range of the signal. The high limit
includes over range signals. This could be a high temperature. A sensor that is stilloperating but sending a signal above the expected limit will cause a FMI 00 to be stored.
Some of the possible causes of a FMI 00 are listed below.
The signal is above normal. The signal is shorted to the +battery circuit. The sensor needs to be calibrated.
This is an example of a sensor that needs calibration. A PWM signal that is at a duty cycleof 80 percent is a valid signal. If the PWM signal has a duty cycle of 81 percent the sensor
is still working, but the sensor signal is above the expected signal limits.
FMI 01 "Data Valid But Below Normal Operating Range"- Every electronic control
system sets a low limit for the expected operating range of the signal. The limit includes
signals that are under the lower limit. The low signal could be the oil pressure signal. The
sensor is still working but sending a signal below the expected limit will cause a FMI 01 tobe stored.
Some of the possible causes of a FMI 01 are listed below.
The signal is below the normal range. The timing is retarded.
8/12/2019 Localizacin y Solucin de Problemas 789c
21/28
This is an example of a PWM sensor. This sensor is not expected to generate a PWM signal
below a duty cycle of 5 percent with zero air pressure. If the sensor generates a signal with
a duty cycle of 4 percent when the engine is shutdown. The sensor is still working but
sending a signal below the expected limit will cause a FMI 01 to be stored.
FMI 02 "Data Erratic, Intermittent or Incorrect"- The signal from a component ispresent. The control that reads the diagnostic information can not read the signal properly.
The signal appears to be gone, unstable or invalid. The data can be correct or incorrect
intermittently. Also, this condition relates to communication between controls. This is an
example of communication between controls. When the monitoring system is looking forthe engine speed from the engine ECM over the Cat Data Link.
There is a failed connection. The signal is intermittent or erratic. The software has been changed. The signal is noisy. The signal is out of range.
FMI 03 "Voltage Above Normal or Shorted High"- The component or system voltageis higher than the limit. FMI 03 most often relates to a signal circuit.
Some of the components that could cause a FMI 03 are listed below.
The sensor or the switch has failed. The harness is damaged. The electronic control module has failed.
Some of the possible causes of a FMI 03 are listed below.
A sensor that has failed and the voltage output is high. Any wiring harness that has a sensor signal wire shorted to a high voltage. A high
voltage is any voltage that is greater than the sensor supply voltage.
A wiring harness that has an open circuit in the sensor signal wire will cause thecontrol to pull up. When this occurs the input circuit is pulled up to the supply
voltage.
A control that has failed will also cause a FMI 03. This is very unlikely.FMI 04 The Voltage is Below Normal or the Voltage is Shorted Low- The component
or system voltage is lower than the limit. FMI 04 most often relates to a signal circuit.
Some of the components that could cause a FMI 04 are listed below.
The sensor or the switch has failed. The harness is damaged. The electronic control has failed.
8/12/2019 Localizacin y Solucin de Problemas 789c
22/28
Some of the possible causes of a FMI 04 are listed below.
A sensor that has failed and the voltage output is low. Any wiring harness that has a sensor signal wire shorted to ground. A failed ECM will also cause a FMI 04. This is very unlikely.
FMI 05 Current Below Normal or Open Circuit- The current through the component or
the system is lower than the limit. FMI 05 is most often related to a driver circuit.
Some of the possible causes of a FMI 05 are listed below.
There is an open circuit or a poor harness connection. There is an open relay. There is a switch in the open position.
FMI 06 Current Above Normal or Grounded Circuit- The current through the
component or the system is higher than the limit. FMI 06 is most often related to a drivercircuit. This fault is very similar to FMI 04.
Some of the possible causes of a FMI 06 are listed below.
There is a short to ground in the harness connection. There is a shorted relay. A failed control will also cause a FMI "06". This is very unlikely.
FMI 07 Mechanical System Not Responding Properly- The control detects a signal thatis sent to a mechanical system and the response is not correct.
Some of the possible causes of a FMI 07 are listed below.
The component responds improperly. The component is stuck in a position. The component has failed. The engine is shut down. The machine is being used improperly.
FMI 08 Abnormal Frequency, Pulse Width or Period- This occurs when the signal isnot in the expected range. FMI 08 can also relate to a faulty sensor.
Some of the possible causes of a FMI 08 are listed below.
The harness connections are intermittent or poor. The engine misfired. The signal is noisy due to nearby interference. There are loose mechanical devices.
8/12/2019 Localizacin y Solucin de Problemas 789c
23/28
FMI 09 Abnormal Update- This relates to communications on the data link. FMI 09
occurs when a control is not able to get information from another control.
Some of the possible causes of a FMI 09 are listed below.
The control module is not communicating on the data link correctly.
The rate of data transmission is abnormal. The data link has failed. There is a mismatch of software.
FMI 10 Abnormal Rate of Change- This relates to a signal that changes too fast. The rate
of change is outside of the expected limit.
FMI 11 "Failure Mode Not Identifiable"- The control identifies more than one FMI as
being responsible for a single failure.
Some of the possible causes of a FMI 11 are listed below.
There is a mechanical failure. There is damage to multiple circuits.
FMI 12 Bad Device or Component- The electronic control sends a signal and the
electronic control expects a response. The control receives no response or the response isincorrect.
Some of the possible causes of a FMI 12 are listed below.
There is a failure of the electronic control.
There is a failure on the data link. There are one or more controls with mismatched software.
FMI 13 Out of Calibration- The electrical signal is not within limits for a specificmechanical condition.
Some of the possible causes of a FMI 13 are listed below.
Calibration is required. The data is out of range.
FMI 14, 15, and 20- These codes are not active.
FMI 16 Parameter Not Available- The control does not support the requested parameter.
FMI 17 Module Not Responding- The control does not respond to the request for data.
FMI 18 Sensor Supply Failure- The sensor power supply in the control has failed.
8/12/2019 Localizacin y Solucin de Problemas 789c
24/28
FMI 19 Condition Not Met- The conditions that are defined by the software were not
met.1 1 0
/sisweb/sisweb/ i01731487
/sisw eb/sisw eb/ /sisw eb/sisw eb/ /sisw eb/product
%2Fsisw eb%2F %2Fsisw eb%2F
Copyright 1993 - 2009 Caterpillar Inc.
Todos los derechos reservados.Red privada para licenciados del SIS.
Sun Nov 22 14:49:02 EST 2009
Localizacin y Solucin de ProblemasProduct Link 121/321
Nmero de medio -RENR7911-06 Fecha de publicacin -01/07/2009 Fecha de actualizacin -28/07/2009
i03440361
Event Code List
SMCS -7569
/sisw eb/sisw eb/ /sisw eb/product
Event codes alert the operator or the technician that an abnormal operating condition existsin one of the machine systems.
When an Electronic Control Module (ECM) activates an event code, the operator or the
technician will be alerted by the Messenger. Most active events will be logged by the ECM.Some events are active only. Active only events are not logged. The events that are active
and the events that are logged can be viewed with the following equipment:
Messenger Caterpillar Electronic Technician (Cat ET)
Warning Levels
The ECM will assign a warning level to an active event code. Event codes are one of threelevels. The level is according to the severity of the abnormal condition. Each warning level
requires a specific response from the operator. The warning levels and the required operator
response are listed below.
http://opencopyrightwindow%28%29/http://opencopyrightwindow%28%29/http://opencopyrightwindow%28%29/http://opencopyrightwindow%28%29/http://opencopyrightwindow%28%29/http://opencopyrightwindow%28%29/8/12/2019 Localizacin y Solucin de Problemas 789c
25/28
Warning Level 1
Warning level 1 alerts the operator that a machine system requires attention. The operator
should check the involved system condition or the operator should perform maintenance onthe involved system at the earliest possible time.
Warning Level 2
Warning level 2 requires changing the operation of the machine or performing a
maintenance procedure. Failure to correct a problem that has caused this warning may
result in damage to the components that are involved in the system.
Warning Level 2S
Warning level 2S requires an immediate change in machine operation in order to avoid
possible damage to the system.
Warning Level 3
Warning level 3 requires an immediate safe shutdown of the machine in order to avoid
damage to the machine or injury to personnel around the machine. The problem that causedthe event must be corrected before machine operation can resume.
Indications and System Response
Caterpillar Electronic Technician (Cat ET) Service Tool
When an abnormal operating condition occurs, the status screen on the Cat ET indicates
that there is an active event.
Event codes are displayed on Cat ET in the following format:
EXXXX Description of the code
The "E" means that the code is an event code. The "XXXX" is a numeric identifier. The
numeric identifier is followed by a description of the code.
Active event codes are listed in ascending numerical order. The code with the lowestnumber is listed first. The active event code is removed from the list when the condition is
no longer present.
Logged Event Codes
Some event codes are logged in the ECM memory. Some event codes are active only. The
logged event codes are listed in chronological order. The most recent code is listed first.
8/12/2019 Localizacin y Solucin de Problemas 789c
26/28
A logged code is cleared from memory when one of the following conditions occur:
The service technician manually clears the code. The code does not reoccur for 1000 hours. A new code is logged and there are already ten logged codes in memory. In this case, the
oldest logged code is cleared.
Note: Always clear logged event codes after investigating and correcting the problem
which generated the code.
List of Event Codes
The following table lists event codes and the recommended responses. Use the Cat ET
service tool in order to determine the event codes that are active or logged.
Table 1
List of Event Codes (EID)
EID LevelDescription Possible Cause and Recommended Response
861 1
Synchronized clock
notification ofmanual synch
required
In a PL321 system using sync-clock and Product Link is not
the master ECM, the Product Link module will automatically
sync to the master ECM hours if the difference is not greater
than 50 hours. If the difference is greater than 50 hours, a
diagnostic will be generated in Cat ET that indicates that a
manual sync is required. In that instance, sync the hours. In
Cat ET, use "Service/Synchronize Service Meter Hours".
21312
Inclusion Geo-
Fencing boundary
violated
Inclusive Geo-Fence sets up a "virtual fence" around a work
site. Once Inclusive Geo-Fence is activated, a report is
generated if the machine leaves the work site area. No repair
or service is required.
21322
Exclusion Geo-
Fencing boundary
violated
Exclusive Geo-Fence sets up a "virtual fence" around areas
that the machine is not allowed to enter. A report is
generated if a machine enters a restricted area. No repair or
service is required.
8/12/2019 Localizacin y Solucin de Problemas 789c
27/28
21332
Time-Fencing
boundary violated
Time Based Fence allows the owner of a machine to choose
the time that a machine can be operated. A report is
generated if the machine is operated outside of the time that
is set for machine operation. No repair or service is required.
6302
Switched Sensor
#1 trip condition is
activated
The Product Link PL300 has four additional inputs that can be
configured in order to monitor switches on the machine.
These inputs can be configured by using Caterpillar Electronic
Technician (Cat ET service tool). Troubleshoot input as setup
by the dealer.
631 2
Switched Sensor
#2 trip condition is
activated
The Product Link PL300 has four additional inputs that can be
configured in order to monitor switches on the machine.
These inputs can be configured by using Caterpillar Electronic
Technician (Cat ET service tool). Troubleshoot input as setup
by the dealer.
6322
Switched Sensor
#3 trip condition is
activated
The Product Link PL300 has four additional inputs that can be
configured in order to monitor switches on the machine.
These inputs can be configured by using Caterpillar Electronic
Technician (Cat ET service tool). Troubleshoot input as setup
by the dealer.
6332
Switched Sensor
#4 trip condition is
activated
The Product Link PL300 has four additional inputs that can be
configured in order to monitor switches on the machine.
These inputs can be configured by using Caterpillar Electronic
Technician (Cat ET service tool). Troubleshoot input as setup
by the dealer.
1 1 0
/sisweb/sisweb/ i03440361
/sisw eb/sisw eb/ /sisw eb/sisw eb/ /sisw eb/product
8/12/2019 Localizacin y Solucin de Problemas 789c
28/28
%2Fsisw eb%2F %2Fsisw eb%2F