t:\project\2019\19-028\docs\contractor\addendum\addendum 02 100421.doc
ADDENDUM #2
Page 1 of 1
ADDENDUM #02 DATE: 10-04-2021 ARTECH DESIGN GROUP, INC. EMS 15 8881 Snowy Owl Road Ooltewah, TN 37363 The following Contract Documents are revised as described below and this voids, supersedes, and takes precedence over previously issued Documents of the same number and item when revised. These revised Documents shall become a part of the General Contractor’s Bid and Contract. DRAWINGS: GENERAL
1. Sheet T1.1 a. Revised sheet Index
2. Sheet T1.2
a. Revised Wall Type 3 b. Added Note in Partition Legend
SPECIFICATIONS: GENERAL
1. Specifications / Project Manual reissued to included previously missing sections.
END OF ADDENDUM
INTERIORS
ARCHITECTURE
CHATTANOOGA, TN 37408
ARTECH DESIGN GROUP, INC.
&1410 COWART STREET
423.265.4313
JOB NO. D'WN CK'D
ISSUE DATESINITIAL ISSUE
19-028 TS RT
HA
MIL
TON
CO
UN
TYEM
S ST
ATI
ON
#15
PR
OJE
CT
NO
. 18-
04-0
1.02
OO
LTEW
AH, T
N
T1.1TITLE SHEET
04-16-20
HAMILTON COUNTYEMS STATION #15
PROJECT NO. 18-04-01.02OOLTEWAH, TN
INDEX OF DRAWINGS
SheetNumber Sheet Name
(04-
16-2
0) IN
ITIA
L IS
SUE
(09-
15-2
1) A
DDEN
DUM
#1
(10-
04-2
1) A
DDEN
DUM
#2
GENERALT1.1 TITLE SHEET X X XT1.2 BUILDING CODE SUMMARY X X XT1.3 LIFE SAFETY PLAN XT1.4 ADA COMPLIANCE STANDARDS XT1.5 ADA COMPLIANCE STANDARDS XT1.6 FIRE RATED ASSEMBLIES X
CIVILC1.0 SITE STAKING X XC2.0 EXISTING CONDITIONS & DEMO PLAN XC3.0 SEDIMENT AND EROSION CONTROL NOTES &
DETAILSX
C3.1 SEDIMENT AND EROSION CONTROL PHASE 1 XC3.2 SEDIMENT AND EROSION CONTROL PHASE 2 X XC4.1 SITE GRADING X XC4.2 SITE DRAINAGE X XC4.7 SEWER FORCE MAIN XC5.0 SITE UTILITIES X XC6.0 LANDSCAPE XC7.0 GENERAL NOTES & DETAILS XC8.0 SITE DETAILS XC9.0 SITE DETAILS XC10.0 WATER DETAILS X X
ARCHITECTURALA1.0 SIDEWALK PLAN XA1.1 FLOOR PLAN XA1.1F FINISH FLOOR PLAN XA2.1 EXTERIOR ELEVATIONS X XA3.1 WALL SECTIONS XA3.2 WALL SECTIONS XA3.3 WALL SECTIONS XA4.1 ROOF PLAN XA5.1 ENLARGED PLANS & DETAILS XA6.1 RESTROOM PLANS & DETAILS XA6.2 INTERIOR ELEVATIONS XA7.1 REFLECTED CEILING PLAN XA8.1 DOOR SCHEDULE & DETAILS X X
STRUCTURALS0.1 GENERAL NOTES XS0.2 SPECIAL INSPECTIONS XS0.3 SECTIONS & DETAILS XS0.31 SECTIONS & DETAILS XS1.0 FOUNDATION PLAN XS2.0 ROOF FRAMING PLAN X
FIRE PROTECTIONFP0.1 FIRE PROTECTION SITE PLAN AND NOTES XFP1.1 FIRE PROTECTION FLOOR PLAN X XFP1.2 FIRE PROTECTION PLAN UPPER XFP1.3 FIRE PROTECTION ATTIC PLAN X
MECHANICALM0.1 MECHANICAL SCHEDULES X XM0.2 MECHANICAL DETAILS XM1.1 MECHANICAL FLOOR PLAN X XM1.2 MECHANICAL PLATFORM PLAN X X
PLUMBINGP0.1 PLUMBING SCHEDULES AND NOTES X XP0.2 PLUMBING DETAILS XP1.1 SANITARY FLOOR PLAN X XP2.1 DOMESTIC FLOOR PLAN X X
ELECTRICALE0.1 ELECTRICAL PROJECT SCHEDULES AND NOTES XE0.2 FIRE ALARM SYSTEM NOTES XE1.1 ELECTRICAL LIGHTING PLANS XE2.1 ELECTRICAL POWER PLAN XE3.1 HVAC POWER PLAN XE4.1 ELECTRCAL RISER DIAGRM XE5.1 ELECTRICAL PANEL SCHEDULES XES1.1 ELECTRICAL SITE PLAN X XES2.1 ELECTRICAL SITE LIGHTING PLAN XES2.2 ELECTRICAL SITE PHOTOMETRIC PLAN X
HAMILTON COUNTY GOVERNMENTMAYOR:
HON. JIM COPPINGER
COUNTY COMMISSIONERS
DISTRICT 1: RANDY FAIRBANKSDISTRICT 2: CHIP BAKERDISTRICT 3: GREG MARTINDISTRICT 4: WARREN MACKEYDISTRICT 5: KATHERLYN GETERDISTRICT 6: DAVID SHARPEDISTRICT 7: SABRENA SMEDLEY- CHAIRMANDISTRICT 8: TIM BOYD- CHAIRMAN PRO-TEMPOREDISTRICT 9: DR. STEVE HIGHLANDER
1 ADD # 1 09-15-212 ADD # 2 10-04-21
2
3 5/8" METAL STUDS 24" O.C. TO BOTTOM OF TRUSS W/ ONE LAYER 5/8" GYPSUM WALL BOARD EACH SIDE.
3 5/8" METAL STUDS 24" O.C. TO BOTTOM OF TRUSS W/ ONE LAYER 5/8" GYPSUM WALL BOARD EACH SIDE W/ 3 1/2" SOUND BATT INSULATION. (USE FIBERGLASS FACED GYPSUM BOARD ON RESTROOM SIDE OR OTHER WET ENVIRONMENT)
3 5/8" METAL STUDS 24" O.C. TO BOTTOM OF TRUSS W/ ONE LAYER 5/8" GYPSUM WALL BOARD.(USE FIBERGLASS FACED GYPSUM BOARD ON RESTROOM SIDE OR OTHER WET ENVIRONMENT)
1
1A
1B
2 1 HR RATED (UL #U465)3 5/8" METAL STUDS 24" O.C. TO BOTTOM OF TRUSS W/ ONE LAYER FIRE RATED G.W.B. EACH SIDE W/ 3 1/2" SOUND BATT INSULATION. BUILD WALL ACCORDING TO UL U465 DESIGN REQUIREMENTS
7 5/8" C.M.U. 2 HOUR RATED (UL# U905)3
NOTE:AT WALL TYPES 2 & 3, AND 1 HOUR RATED CEILING ASSEMBLIES:
1. STENCIL WALLS ABOVE CEILINGS @ 8' MIN O.C. "1 HOUR FIRE RATED" OR "2 HOUR FIRE RATED" AS APPROPRIATE. COLOR "RED", FONT TO BE HELVETICA, 2" TALL LETTERS.
2. ALL PENETRATIONS TO BE FIRE CAULKED COMPLETELY. ACCEPTABLE PRODUCTS ARE BY 3M, HILTI, STI ONLY, AND AS RECOMMENDED BY MFR. FOR SPECIFIC CONDITION APPLICATION. APPLICATOR MUST HAVE MANUFACTURERS CERTIFICATIONS AND PROVIDE SUCH CERTIFICATION WITH PRODUCT INFORMATION FOR APPROVAL BY ARCHITECT.
1 View NameSCALE:1/8" = 1'-0"
1i
XX
+XX'
TITLE SYMBOL
SECTION SYMBOLSECTION #XSHEET #AX.X
DETAIL SYMBOLDETAIL #XSHEET #AX.X
ENLARGED DETAIL SYMBOLDETAIL #XSHEET #AX.X
INTERIOR ELEVATION SYMBOLELEVATION #XXSHEET #AX.X
EXTERIOR ELEVATION SYMBOLELEVATION #XXSHEET #AX.X
INTERIOR ROOM SYMBOLROOM #XXX
DOOR SYMBOLDOOR #XXX
STOREFRONT SYMBOLSEE STOREFRONT SCHEDULE
WALL TYPES SYMBOLSEE WALL/PARTITION LEGEND
FINISH ELEVATION SYMBOLELEVATION NUMBER
REVISION SYMBOL
AX.X
XX
AX.X XX
AX.X1
SIM
AX.X1
SIM
AX.X1
SIM
XX
XXRoom Name
1
NAME OF PROJECT:
ADDRESS:
PROPOSED USE:
OWNER/CONTACT PERSON:
CODE ENFORCEMENT JURISDICTION:
HAMILTON COUNTY EMS STATION #5 PROJECT # 18-04-01.02
OOLTEWAH, TN
EMERGENCY MEDICAL SERVICES HOUSING VEHICLES (S-2) AND EMS TECHNICIANS (R2)
AUTUMN FRIDAY
HAMILTON COUNTY, TN
PHONE: (423) 290-7821
PROJECT INFORMATION
APPLICABLE CODES
ARCHITECTURAL:
ELECTRICAL:
PLUMBING:
MECHANICAL:
LIFE SAFETY:
GAS:
ENERGY:
ACCESSIBILITY:
2012 INTERNATIONAL BUILDING CODE
DESIGNER OF RECORD
DESIGNER
ARCHITECTURAL:
ELECTRICAL:
PLUMBING:
MECHANICAL:
STRUCTURAL:
CIVIL:
NAME LICENSE # TELEPHONE #
RICHARD D. THOMPSON 17840 (423) 265-4313
STEVEN B. SABACKY 111301 (423) 664-1485
C.JEFFERY WESTBROOK 10599 (423) 698-6675
C.JEFFERY WESTBROOK 10599 (423) 698-6675
THOMAS F. IRELAND 21225 (423) 756-7943
JOE B. HUTCHERSON 114155 (423) 664-1450
BUILDING DATA
OCCUPANCY TYPE:
MIXED OCCUPANCY:
CONSTRUCTION TYPE:
SPRINKLED:
FIRE DISTRICT:
BUILDING HEIGHT:
MEZZANINE:
HIGH RISE:
GROSS BUILDING AREA:
GROSS AREA ALLOWED:
AREA INCREASE:
STORAGE (S-2), RESIDENTIAL (R2)
YES
YES
NO
NO
NO
NO
IIIB MIXED CONSTRUCTION: YES
SEPARATION: 1HR
24'-10" NUMBER OF STORIES: 1
FIRE RESISTANCE RATINGS
EXTERIOR BEARING WALLS:
EXTERIOR NON-BEARING WALLS:
NORTH
EAST
WEST
SOUTH
NORTH
EAST
WEST
SOUTH
INTERIOR WALLS:
BEARING
NON-BEARING
PARTY/FIRE WALLS:
REQUIRED HOURLY
DETAIL # & SHEET #
% WALL OPENING
DESIGN # FOR RATED ASSEMBLIES
NA NA NA NA
2HR NA NA UL-U904
2HR NA NA UL-U904
2HR NA NA UL-U904
2HR NA NA UL-U904
NA NA NA NA
NA NA NA NA
NA NA NA NA
NA NA NA NA
NA NA NA NA
NA NA NA NA
CEILING-FLOORS ASSEMBLY:
BEAMS:
COLUMNS:
CEILING-ROOF ASSEMBLY(R2 DWELLING UNIT ONLY):
VERTICAL SHAFTS:
CHASES - P.E.M.:
MIXED OCCUPANCY SEPARATION:
TENANT SEPARATION:
NA NA NA NA
NA NA NA NA
NA NA NA NA
1 NA NA UL-P522
NA NA NA NA
NA NA NA NA
1 NA NA UL-U904
NA NA NA NA
LIFE SAFETY SYSTEMS
EMERGENCY LIGHTING AND EXIT SIGNS:
FIRE ALARM AND SMOKE DETECTOR SYSTEMS:
PANIC HARDWARE:
EXIT REQUIREMENTS
DEAD END LIMIT-MAXIMUM CONDITION:
TRAVEL DISTANCE TO EXIT - MAXIMUM CONDITION:
NOTE: SEE LIFE SAFETY PLAN ON SHEET T1.3
YES
YES
YES
50'
(S-2) 400' (R-2) 250'
TOTAL FIXTURE SUMMARY TOTAL OCCUPANT LOAD: 13
FIXTURES - MALE & FEMALE
LAVATORIES
WATER CLOSETS
REQUIRED PROVIDED
2 2
2 2
2017 NATIONAL ELECTRIC CODE
2012 INTERNATIONAL PLUMBING CODE
2012 INTERNATIONAL MECHANICAL CODE
2012 INTERNATIONAL FIRE CODE
2012 INTERNATIONAL FUEL/GAS CODE
2009 INTERNATIONAL ENERGY CONSERVATION CODE
2009 ICC/ANSI A117
2,936 SQ FT
16,000 SQ FT
BATHTUB/SHOWER 2 2
DRINKING FOUNTAIN 0 0
SERVICE SINK 1 1
DWELLING UNITS PER:708.3 EXCEPTION 2
1/2 HOURPROVIDED 1
NA NA UL-U465
CONSTRUCTION ELEMENT
THERMAL ENERGY SYNOPSISPROVIDED
VALUE ASSEMBLY DESCRIPTION
ROOFS R-38
11.4 CI
R-10 FOR 24" BELOW
U-0.15
NA
NA
METAL ROOFING OVER WOOD TRUSSES WITH ATTIC
INTERIOR CONTINUOUS INSULATION ON MASONRY WALLS
4" SLAB ON 6" COMPACTED FILL WITH R-10 PERMITER INSULATION
INSULATED METAL EXIT DOOR
ALUMINUM FRAMED INSULATED GLAZING.27/.25
EXTERIOR WALLS, ABOVE GRADE
MASS (R-2)
SLAB ON GRADE FLOORS
OPAQUE DOORS (SWINGING)
FENESTRATION U FACTOR/ SHGC
STOREFRONT
ENTRY DOORS
WINDOWS
THERMAL ENVELOPE NOTES:
1. THERMAL ENVELOPE AND ENERGY EFFICIENCY ELEMENTS SHALL MEET THE REQUIREMENTS OF THE INTERNATIONAL ENERGY CONSERVATION CODE (IECC) - 2009
2. THE CLIMATE ZONE FOR THIS PROJECT AS DETERMINED IN IECC CHAPTER 3 IS ZONE 4A.
3. THE ASSEMBLIES LISTED ABOVE COMPLY WITH THE IECC REQUIREMENTS UNDER THE FOLLOWING METHOD: COMPLIANCE USING ASHRAE/IESNA 90.1 PER SECTION 501 OF IECC
LEGEND: NR - NO REQUIREMENT NA - NOT APPLICABLE CI - CONTINUOUS INSULATION
REQUIREDVALUE
R-38
9.5 CI
NR
U-0.7
NA
NA
.5/.4
N
SITE
N
SITE
SNOWY OWL ROADSNOWY OWL ROAD
MORGAN FARM LN
INTERIORS
ARCHITECTURE
CHATTANOOGA, TN 37408
ARTECH DESIGN GROUP, INC.
&1410 COWART STREET
423.265.4313
JOB NO. D'WN CK'D
ISSUE DATESINITIAL ISSUE
19-028 TS RT
HA
MIL
TON
CO
UN
TYEM
S ST
ATI
ON
#15
PR
OJE
CT
NO
. 18-
04-0
1.02
OO
LTEW
AH, T
N
T1.2BUILDING CODE
SUMMARY
04-16-20
1. REFER TO WALL SECTIONS FOR CONSTRUCTION OF EXTERIOR WALLS.2. SPECIAL CONDITIONS AND SPECIAL PARTITIONS ARE INDICATED ON PLANS AND DETAILS.3. WALLS SHOWN WITH MORE THAN ONE INDICATOR SHALL CONTAIN ALL COMPONENTS OF THE WALL TYPES INDICATED.4. ALL INTERIOR STUD SPACING TO BE 24" O.C. UNLESS NOTED OTHERWISE.5. ALL INTERIOR METAL STUD WALLS TO BE 20 GAUGE UNLESS NOTED OTHERWISE.6. WHERE STUDS EXTEND TO ROOF DECK, PROVIDE A SLIP JOINT TRACK (SUPERIOR METAL TRIM, SFT TYPE 53 OR EQUAL)7. PROVIDE SOLID WOOD BLOCKING IN WALLS AT ALL TOILET ACCESSORY, DOOR STOP AND TOILET PARTITION LOCATIONS, AS REQUIRED.
1. WHERE A DETAIL IS SHOWN OR NOTE IS DESCRIBED FOR ONE CONDITION IT SHALL APPLY FOR ALL LIKE OR SIMILAR CONDITIONS EVEN THOUGH NOT SPECIFICALLY MARKED ON THE DRAWINGS
2. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND LOCATIONS AFFECTING THIS PROJECT PRIOR TO FABRICATION OR INSTALLATION OF NEW WORK. NOTIFY ARCHITECT OF ANY DISCREPANCIES FROM DIMENSIONS SHOWN, NOTED OR REQUIRED. ADJUST DIMENSIONS OF NEW CONSTRUCTION AT DIRECTION OF ARCHITECT TO ALLOW FOR ACTUAL FIELD DIMENSIONS.
3. PROVIDE OPENINGS WITH LINTELS OR HEADERS IN WALLS/PARTITIONS AS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING WORK.
4. PROVIDE WOOD BLOCKING AS REQUIRED IN WALLS FOR ALL WALL MOUNTED CASEWORK, SHELVES, EQUIPMENT, ACCESSORIES, AND AS INDICATED FOR INSTALLATION OF EQUIPMENT BY OTHERS.
5. WOOD BLOCKING AND/OR NAILERS ARE GENERALLY SHOWN IN A GENERIC FASHION -CONTRACTOR MUST COORDINATE EXACT BLOCKING REQUIREMENTS WITH COMPONENT MANUFACTURER'S SUGGESTIONS OR STANDARDS, AND WITH OTHER TRADES.
WALL LEGEND
WALL/PARTITION NOTES:
PARTITION LEGEND:
GENERAL NOTES
SYMBOLS
CONTACT LIST
VICINITY MAP CODE SUMMARY
KEY PLAN
ENERGY
ARCHITECT:ARTECH DESIGN GROUP1410 COWART STREETCHATTANOOGA, TN 37408CONTACT: RICE WILLIAMS P:(423) 643-0653EMAIL: [email protected]
OWNER:HAMILTON COUNTY DEPARTMENT OF ENGINEERIING1250 MARKET STREET SUITE 3050CHATTANOOGA, TN 37402CONTACT: AUTUMN FRIDAY P:(423) 209-7821EMAIL: [email protected]
ENGINEERS:MARCH ADAMS (CIVIL AND MEP)310 DODDS AVENUECHATTANOOGA, TN 37404CONTACT: JEFF WESTBROOK P:(423) 664-1470EMAIL: [email protected]
BENNETT AND PLESS, INC. (STRUCTURAL)1301 RIVERFRONT PARKWAY SUITE 104CHATTANOOGA, TN 37404CONTACT: TOMMY IRELAND P:(423) 756-7943EMAIL: [email protected]
1 ADD # 1 09-15-212 ADD # 2 10-04-21
2