Censo de carga:
A-Tipo de servicio: MonofásicoB-Nivel de tensión: 230v IT
C-Corriente: 32AD-Criterio preliminar de carga: 5,3kw
e-Censo de carga: 4,77kw/Reserva:6,36kwF-Grado de electrificación de la vivienda: MediaG-Tipo de acometida (aérea, subterránea): Aérea
PLANTEO:
Superficie: 11mx8m=88m P=88x0,060=5,3kw/m 11 toma Corrientes: 4000w/4kw
14 Lamp.incandescentes: 14.40w=560w/0,560kw 5300w----------100% 4 tubos de luz: 4.40w.1,3=208w/0,208kw X---------------20%
1 timbre: 8w/0,008kw X=1060wPT=4000w+560w+208w+8w=4776w/4,77kwReserva 20%:5300w+1060=6360w/6,36kw
Potencia a solicitar según tabla: 7,4kw
CALCULO DE METRAJE DE DERIVACIONES:
LtWt = 700 x 5,95 = 4165LtWt = 4165W = 700wL = 4165/700 = 5,95m
2,60
1,50
1,10
1,10
3,35
1,50
DERIVACION 1:
2,60
1,50
1,10
0,30
2,80
1,501,10
0,50
2,30
LtWt = 1200 x 9,7 = 11640LtWt = 11640W = 1200wL = 11640/1200 = 9,7m
DERIVACION 2:
2,60
1,50
1,10
1,10
1,00
1,50
0,15
0,951,6040w LtWt = 40x 6,05 + 40 x 6,85 = 516LtWt = 516W = 80wL = 516/80 = 6,45m
40w
DERIVACION 3:
LtWt = 8 x 4,65 = 37,2LtWt = 37,2W = 8wL = 37,2/8 = 4,65m
0,20
1,10
1,50
0,200,15 2,60
1,50
1,10
DERIVACION 4:
2,60
1,50
1,10
1,10
2,951,90
1,50
2,151,7040w LtWt = 40 x 18,8 + 40 x 10,65 + 40 x 11,45 =
1636LtWt = 1636W = 120wL = 1636/120 = 13,63m
0,8040w 40w
2,10
2S1,50
DERIVACION 5:
2,60
1,50
0,30
1,10
6,551,00
2,30
LtWt = 700 x 9,95 + 700 x 15,55 = 17850LtWt = 17850W = 1400wL = 17850/1400 = 12,75m
DERIVACION 6:
2,85
1,10
1,50
2,60
1,50
1,10
1,30
40w
LtWt = 40 x 8,25 = 330LtWt = 330W = 40wL = 330/40 = 8,25m
DERIVACION 7:
2,60
1,50
0,30
1,10
3,903,30
2,30
LtWt = 700 x 7,3 + 700 x 15,2 = 15750LtWt = 15750W = 1400wL = 15750/1400 = 11,25m
DERIVACION 8:
2,60
1,50
1,10
1,10
4,200,15
1,50
0,15
2,601,20 5,7540w LtWt = 40 x 10,9 + 40 x 16,65 + 40 x 12,65 + 40 x 18,8 + 40 x 20,55 + 40 x 24,05 = 4144LtWt = 4144W = 240wL = 4144/240 = 17,26m
40w
40w40w40w1,70 1,80 1,75 4,20
DERIVACION 9:
2,60
1,50
1,10
1,10
1,352,20
1,50
0,402,8040w 40w40w40w
4,902,30
40w40w
0,30
LtWt = 40 x 5,85 + 40 x 8,65 + 40 x 11,95 + 40 x 12 + 40 x 13,25 + 40 x 18,15 = 2794LtWt = 2794W = 240wL = 2794/240 = 11,64m
DERIVACION 10:
LtWt = 700 x 7,5 = 5250LtWt = 5250W = 700wL = 5250/700 = 7,5m
2,60
1,50
1,10
1,10
4,90
1,50
DERIVACION 11:
LtWt = 700 x 5,25 + 700 x 9,1 = 10045LtWt = 10045W = 1400wL = 10045/1400 = 7,175m
2,60
1,50
1,10
1,10
2,650,85
1,50
DERIVACION 12:
2,60
1,50
0,30
1,10
3,793,00
2,30
LtWt = 700 x 7,1 + 700 x 14,7 = 15260LtWt = 15260W = 1400wL = 15260/1400 = 10,9m
DERIVACION 13:
0,30
1,10
1,50
2,60
1,50
1,10
40w1,75 LtWt = 40 x 8,9 = 356
LtWt = 356W = 40wL = 356/40 = 8,9m
1,25
DERIVACION 14:
CALCULO DE SECCIONES:LINEA GENERAL Y TABLERO:
Sv = 4,08mm2
Si = 4mm2
Sm = 6mm2
Sn = 6mm2
5,407,4kw
ICP TG
17,26m
5,40
1,101,10
ICP TG
LG = 1,10m + 1,10m + 5,40m = 7,6m3% de 230v = 6,9v2,1v + 4,8v = 6,9v
PLANTEO:7,6m + 17,26m = 24,86m24,86m = 6,9v1m = 6,9v/24,86m7,6m: 6,9v x 7,6m/24,86m = 2,1v (Caída de tensión para línea general)17,26m: 6,9v x 17,26m/24,86m = 4,8v (Caída de tensión para el tablero)S = 2LW/kev = 2 x 7,6m x 7400w/57 x 2,1v x 230v = 4,08mm2
P = V x II = P/V = 7400w/230v = 32,17A ----- 4mm2
DERIVACION 1:
S = 2LW/kev = 2 x 5,95m x 700w/57 x 4,8v x 230v = 0,13mm2I = P/V = 700w/230v = 3,04A ----- 0,75mm2
DERIVACION 2:
S = 2LW/kev = 2 x 9,7m x 1200w/57 x 4,8v x 230v = 0,36mm2I = P/V = 1200w/230v = 5,21A ----- 0,75mm2
DERIVACION 3:
S = 2LW/kev = 2 x 6,45m x 80w/57 x 4,8v x 230v = 0,016mm2I = P/V = 80w/230v = 0,35A ----- 0,75mm2
DERIVACION 4:
S = 2LW/kev = 2 x 4,65m x 8w/57 x 4,8v x 230v = 0,0012mm2I = P/V = 8w/230v = 0,035A ----- 0,75mm2
DERIVACION 5:
S = 2LW/kev = 2 x 13,63m x 120w/57 x 4,8v x 230v = 0,052mm2I = P/V = 120w/230v = 0,52A ----- 0,75mm2
Sv = 0,13mm2
Si = 0,75mm2
Sm = 1,0mm2
Sn = 1,0mm2
Sv = 0,36mm2
Si = 0,75mm2
Sm = 1,0mm2
Sn = 1,0mm2
Sv = 0,016mm2
Si = 0,75mm2
Sm = 0,75mm2
Sn = 0,75mm2
Sv = 0,0012mm2
Si = 0,75mm2
Sm = 0,75mm2
Sn = 0,75mm2
Sv = 0,052mm2
Si = 0,75mm2
Sm = 0,75mm2
Sn = 0,75mm2
DERIVACION 6:
S = 2LW/kev = 2 x 12,75m x 1400w/57 x 4,8v x 230v = 0,057mm2I = P/V = 1400w/230v = 6,08A ----- 0,75mm2
DERIVACION 7:
S = 2LW/kev = 2 x 8,25m x 40w/57 x 4,8v x 230v = 0,010mm2I = P/V = 40w/230v = 0,17A ----- 0,75mm2
DERIVACION 8:
S = 2LW/kev = 2 x 11,25m x 1400w/57 x 4,8v x 230v = 0,50mm2I = P/V = 1400w/230v = 6,09A ----- 0,75mm2
DERIVACION 9:
S = 2LW/kev = 2 x 17,26m x 240w/57 x 4,8v x 230v = 0,13mm2I = P/V = 240w/230v = 1,04A ----- 0,75mm2
DERIVACION 10:
S = 2LW/kev = 2 x 11,64m x 240w/57 x 4,8v x 230v = 0,088mm2I = P/V = 240w/230v = 1,04A ----- 0,75mm2
Sv = 0,57mm2
Si = 0,75mm2
Sm = 1,5mm2
Sn = 1,5mm2
Sv = 0,010mm2
Si = 0,75mm2
Sm = 0,75mm2
Sn = 0,75mm2
Sv = 0,50mm2
Si = 0,75mm2
Sm = 1,5mm2
Sn = 1,5mm2
Sv = 0,13mm2
Si = 0,75mm2
Sm = 0,75mm2
Sn = 0,75mm2
Sv = 0,57mm2
Si = 0,75mm2
Sm = 0,75mm2
Sn = 0,75mm2
DERIVACION 11:
S = 2LW/kev = 2 x 7,5m x 700w/57 x 4,8v x 230v = 0,17mm2I = P/V = 7000w/230v = 3,04A ----- 0,75mm2
DERIVACION 12:
S = 2LW/kev = 2 x 7,175m x 1400w/57 x 4,8v x 230v = 0,32mm2I = P/V = 1400w/230v = 6,09A ----- 0,75mm2
DERIVACION 13:
S = 2LW/kev = 2 x 10,9m x 1400w/57 x 4,8v x 230v = 0,48mm2I = P/V = 1400w/230v = 6,09A ----- 0,75mm2
DERIVACION 14:
S = 2LW/kev = 2 x 8,9m x 40w/57 x 4,8v x 230v = 0,01mm2I = P/V = 40w/230v = 0,17A ----- 0,75mm2
Sv = 0,17mm2
Si = 0,75mm2
Sm = 1,0mm2
Sn = 1,0mm2
Sv = 0,32mm2
Si = 0,75mm2
Sm = 1,5mm2
Sn = 1,5mm2
Sv = 0,48mm2
Si = 0,75mm2
Sm = 1,5mm2
Sn = 1,5mm2
Sv = 0,01mm2
Si = 0,75mm2
Sm = 0,75mm2
Sn = 0,75mm2
PROVISORIO DE OBRA:
Se realizara un censo de carga de iluminación y un censo de maquinas y luego elcenso total por un 10% más.
MAQUINARIA A UTILIZAR EN EL PROVISORIO DE OBRA:
Un trompo: 375wUn taladro: 600wUna esmeriladora: 800w2 luces de Hg: 500wUna sierra circular portátil: 800w
A-Tipo de servicio: MonofásicoB-Nivel de tensión: 230v ITC-Corriente: 20AD-Criterio preliminar de carga: 5,28kwe-Censo de carga: 3,075kwF-Grado de electrificación de la vivienda: BajaG-Tipo de acometida (aérea, subterránea): Aérea
PLANTEO:
Superficie: 11mx8m=88m P=88x0,060=5,3kw/mPT=375w+600w+800w+500wx2+800w=3075w/3,075kwPotencia a solicitar según tabla: 4,6kw